Repair verified & closed
Written 4/21/26 by Marcus H.
Findings summary
IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2.
Formal write-up
Title
Tube wall loss, IRIS
Cause
Erosion
Findings
IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2.
Measurements
—
Recommendation
Plug the 6 tubes and expand IRIS to 100% of rows 1 to 3.
Justification
—
NotesNot printed
—
RR complete (initial & date)
Repair complete, verified by inspection.
Photos (0)