Your Inspection Co.
API Inspection / Repair Recommendation
| Site | Calder Bay Complex | RR # | RR-018-D-1425 |
|---|---|---|---|
| Equipment ID | D-1425 | ||
| Process Description | Vertical vessel | ||
| Inspector | Marcus H. | ||
| Date of Finding | 4/21/26 | ||
| EWO / Client WO # | — |
FINDINGS:
During the 2026 U14 Turnaround, visual inspection of D-1425 (Vertical vessel) revealed: IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2.
RECOMMENDATIONS:
Plug the 6 tubes and expand IRIS to 100% of rows 1 to 3.
JUSTIFICATION(S):
No justification recorded.
PHOTO REFERENCE:
No photos attached.