Exchangers
E-1401A
AES shell and tube
Closed outRenee T. — locked
0 RRs · 0 open
Closed out — this record is locked. Cell edits, log entries and new RRs are off until an admin reopens it.
Administrative notes
Internal only.
Wallchart — E-1401A
Click a cell to sign it or add a note. A red pill is an RR — click it to open.
1 of 1 items · click a cell to edit, drag a column edge to resize
| Equip # | Equipment Name | Work Order | Description | Progress | Scope | Component | Status | VI | Flanges VI | ECT/RFT/IRIS | UTT | Final QA | Repair Recommendation (RR) | Repair Complete | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| E-1401A | Crude / Diesel Exchanger | WO-48982 | AES shell and tube | Closed out | Pull bundle, VI all components, IRIS 20% tubes | Channel (Bonnet) | Boxed up | KJ 04/16 Minor general corrosion, within allowance | CV 04/19 Light scale, no pitting | N/A | MH 04/30 No cracking found | OS 05/07 | · | ○︎ | ○︎ |
| WO-48982 | Shell | RC 04/16 | OS 04/18 | N/A | AK 04/30 Light scale, no pitting | MH 05/04 | · | ○︎ | ○︎ | ||||||
| WO-48982 | Tube Bundle | DP 04/13 | MH 04/19 | DP 04/27 | OS 04/29 No cracking found | CV 05/03 | · | ○︎ | ○︎ | ||||||
| WO-48982 | Floating Head | DP 04/15 | GW 04/19 Coating intact | N/A | KJ 04/29 | CV 05/06 | · | ○︎ | ○︎ |