Wallchart — E-1407A
Click a cell to sign it or add a note. A red pill is an RR — click it to open.
1 of 1 items · click a cell to edit, drag a column edge to resize
| Equip # | Equipment Name | Work Order | Description | Progress | Scope | Component | Status | VI | Flanges VI | ECT/RFT/IRIS | UTT | Final QA | Repair Recommendation (RR) | Repair Complete | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| E-1407A | Diesel Product Cooler | WO-48937 | AEL fixed tubesheet | Closed out | Pull bundle, VI all components, IRIS 20% tubes | Channel (Bonnet) | Boxed up | CV 04/16 | DP 04/19 | N/A | PN 05/01 Light scale, no pitting | AK 05/07 | · | ○︎ | ○︎ |
| WO-48937 | Shell | DP 04/16 | OS 04/18 Minor general corrosion, within allowance | N/A | LO 04/28 Coating intact | DP 05/05 | · | ○︎ | ○︎ | ||||||
| WO-48937 | Tube Bundle | OS 04/17 No cracking found | OS 04/21 Gaskets surfaces good | KJ 04/22 Minor general corrosion, within allowance | RC 04/27 | AK 05/05 | · | ○︎ | ○︎ | ||||||
| WO-48937 | Floating Head | KJ 04/12 | KJ 04/18 | N/A | PN 05/02 Gaskets surfaces good | RC 05/06 | · | ○︎ | ○︎ |