Rolling log
18 entriesKendra J.of 248
| Inspection details | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 5/7/26 | Nights | Kendra J. | Exchangers | E-1403B Kero Pumparound Cooler | Shell | Final QA complete | — | — | — | — | |
| 5/6/26 | Nights | Kendra J. | Exchangers | E-1408A Naphtha Cooler | Tube Bundle | Final QA complete | — | — | — | — | |
| 5/3/26 | Nights | Kendra J. | Exchangers | E-1404A Feed / Effluent Exchanger | Floating Head | Final QA complete | — | — | — | — | |
| 5/2/26 | Nights | Kendra J. | Exchangers | E-1405A Reboiler | Tube Bundle | UTT complete. Light scale, no pitting | — | — | — | — | |
| 4/30/26 | Nights | Kendra J. | PSV Pull | PSV-14306 | — | Outlet Piping VT complete | — | — | — | — | |
| 4/29/26 | Nights | Kendra J. | Exchangers | E-1401A Crude / Diesel Exchanger | Floating Head | UTT complete | — | — | — | — | |
| 4/24/26 | Nights | Kendra J. | PSV Pull | PSV-14314 | — | Inlet Piping VT complete. No cracking found | — | — | — | — | |
| 4/22/26 | Nights | Kendra J. | Exchangers | E-1407A Diesel Product Cooler | Tube Bundle | ECT/RFT/IRIS complete. Minor general corrosion, within allowance | — | — | — | — | |
| 4/22/26 | Nights | Kendra J. | Drums | D-1431 Steam Drum | — | UTT complete. No recordable indications | — | — | — | — | |
| 4/21/26 | Nights | Kendra J. | Exchangers | E-1406B Trim Cooler | Tube Bundle | Flanges VI complete. Coating intact | — | — | — | — | |
| 4/20/26 | Nights | Kendra J. | Exchangers | E-1406B Trim Cooler | Channel (Bonnet) | Flanges VI complete | — | — | — | — | |
| 4/18/26 | Nights | Kendra J. | Exchangers | E-1407A Diesel Product Cooler | Floating Head | Flanges VI complete | — | — | — | — | |
| 4/18/26 | Nights | Kendra J. | PSV Pull | PSV-14314 | — | PSV Removed complete. Minor general corrosion, within allowance | — | — | — | — | |
| 4/16/26 | Nights | Kendra J. | Exchangers | E-1401A Crude / Diesel Exchanger | Channel (Bonnet) | VI complete. Minor general corrosion, within allowance | — | — | — | — | |
| 4/16/26 | Nights | Kendra J. | Exchangers | E-1408A Naphtha Cooler | Floating Head | VI complete. Light scale, no pitting | — | — | — | — | |
| 4/14/26 | Nights | Kendra J. | Drums | D-1419 Fuel Gas KO Drum | — | Internal Visual complete | — | — | — | — | |
| 4/12/26 | Nights | Kendra J. | PSV Pull | PSV-14306 | — | PSV Removed complete. No recordable indications | — | — | — | — | |
| 4/12/26 | Nights | Kendra J. | Exchangers | E-1407A Diesel Product Cooler | Floating Head | VI complete | — | — | — | — |