RR-018-D-1425
D-1425
Drums
IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2.
—
Marcus H.
4/21/26
Repair verified & closed
—
RR-019-PSV-14308
PSV-14308
PSV Pull
WFMT found a 1.5 in. linear indication at the toe of the N3 nozzle-to-shell weld.
—
Hollis B.
4/24/26
Repair verified & closed
—
RR-020-PSV-14306
PSV-14306
PSV Pull
Trays 14 and 15 have two dislodged valve caps and one bent support beam.
—
Megan F.
4/27/26
Repair verified & closed
—