| RR # | Equipment / package | Asset type | Finding | EWO # | Written by | Written | Stage | Status |
|---|---|---|---|---|---|---|---|---|
| RR-009-E-2112B | E-2112B | Exchangers | Pitting up to 0.090 in. deep in a 6 in. x 8 in. area at the 6 o'clock position of the bottom head. Remaining wall 0.410 in. against a 0.375 in. minimum. | — | Tasha R. | 11/16/26 | Awaiting client | — |
| RR-010-E-2103B | E-2103B | Exchangers | IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2. | — | Marcus H. | 11/17/26 | Awaiting client | — |
| RR-011-8"-P-2138-C1 | 8"-P-2138-C1 | Pipe & Valves | WFMT found a 1.5 in. linear indication at the toe of the N3 nozzle-to-shell weld. | — | Hollis B. | 11/17/26 | Awaiting client | — |