| RR # | Equipment / package | Asset type | Finding | EWO # | Written by | Written | Stage | Status |
|---|---|---|---|---|---|---|---|---|
| RR-001-E-2118B | E-2118B | Exchangers | Pitting up to 0.090 in. deep in a 6 in. x 8 in. area at the 6 o'clock position of the bottom head. Remaining wall 0.410 in. against a 0.375 in. minimum. | — | Megan F. | 11/12/26 | Repair verified & closed | — |
| RR-002-H-2102 | H-2102 | Heaters | IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2. | — | Marcus H. | 11/12/26 | Repair verified & closed | — |
| RR-003-E-2104A | E-2104A | Exchangers | WFMT found a 1.5 in. linear indication at the toe of the N3 nozzle-to-shell weld. | — | Dwayne P. | 11/13/26 | Client approved | — |
| RR-004-D-2194 | D-2194 | Drums | Trays 14 and 15 have two dislodged valve caps and one bent support beam. | — | Andre K. | 11/13/26 | Client approved | — |
| RR-005-PSV-21378 | PSV-21378 | PSV Pull | Pitting across the gasket seating face of the channel flange, deepest 0.060 in. | — | Dwayne P. | 11/14/26 | Client approved | — |
| RR-006-E-2115B | E-2115B | Exchangers | About 12 sq ft of spalled castable on the north radiant wall, anchors exposed. | — | Dwayne P. | 11/14/26 | Client approved | — |
| RR-007-E-2129A | E-2129A | Exchangers | UTT at CML 7 read 0.188 in. against a 0.200 in. retirement thickness. | — | Megan F. | 11/15/26 | Client deferred | — |
| RR-009-E-2112B | E-2112B | Exchangers | Pitting up to 0.090 in. deep in a 6 in. x 8 in. area at the 6 o'clock position of the bottom head. Remaining wall 0.410 in. against a 0.375 in. minimum. | — | Tasha R. | 11/16/26 | Awaiting client | — |
| RR-010-E-2103B | E-2103B | Exchangers | IRIS on 20% of tubes found 6 tubes with wall loss over 40% at the inlet end, rows 1 and 2. | — | Marcus H. | 11/17/26 | Awaiting client | — |
| RR-011-8"-P-2138-C1 | 8"-P-2138-C1 | Pipe & Valves | WFMT found a 1.5 in. linear indication at the toe of the N3 nozzle-to-shell weld. | — | Hollis B. | 11/17/26 | Awaiting client | — |
| RR-016-D-2110 | D-2110 | Drums | Weeping at 3 plugs on the inlet header box, threads galled. | — | Priya N. | 11/20/26 | Client approved | — |
| RR-017-E-2110A | E-2110A | Exchangers | Pitting up to 0.090 in. deep in a 6 in. x 8 in. area at the 6 o'clock position of the bottom head. Remaining wall 0.410 in. against a 0.375 in. minimum. | — | Priya N. | 11/21/26 | Client deferred | — |