Calder Bay Complex · U14
PSV Pull
10 in scope · 10 closed out · 0 open RRs
10 of 10 items · drag a column edge to resize
| PSV # | Service | Progress | Set Pressure | PSV Removed | Inlet Piping VT | Outlet Piping VT | PSV Installed | Comments |
|---|---|---|---|---|---|---|---|---|
| PSV-14300 | Overhead Accumulator | Closed out | 165 psig | CV 04/17 Gaskets surfaces good | AK 04/18 | MF 04/27 Minor general corrosion, within allowance | MF 05/03 | ○︎ |
| PSV-14302 | Fuel Gas KO | Closed out | 150 psig | HB 04/14 Coating intact | RC 04/19 | MF 04/29 Light scale, no pitting | OS 05/07 Light scale, no pitting | ○︎ |
| PSV-14304 | Steam Header | Closed out | 150 psig | WD 04/16 | LO 04/22 Gaskets surfaces good | LO 04/25 | PN 05/07 No recordable indications | ○︎ |
| PSV-14306 | Exchanger Shell Side | Closed out | 165 psig | KJ 04/12 No recordable indications | DP 04/21 | KJ 04/30 | MF 05/07 | ○︎ |
| PSV-14308 | Pump Discharge | Closed out | 285 psig | MH 04/18 | LO 04/21 | CV 04/27 No cracking found | WD 05/05 Minor general corrosion, within allowance | ○︎ |
| Rendering 5 more… | ||||||||