RR Log
One continuous sequence across the whole site — RR # order is written order, numbers are never reused.
Export CSV
Log activity
Total
17
Filtering
Partial
1
Filtering
Awaiting supervisor review
3
Filtering
Awaiting client
3
Filtering
Client approved
5
Filtering
Client deferred
2
Filtering
Lead deferred
1
Filtering
Closed
2
Filtering
Filter:
Last 24 hours
Last 7 days
Last month
All
All asset types
Drums
Exchangers
Fin Fans
Heaters
PSV Pull
Pipe & Valves
All equipment
8"-P-2138-C1
D-2110
D-2164
D-2194
E-2103B
E-2104A
E-2109B
E-2110A
E-2111A
E-2112B
E-2115B
E-2118B
E-2129A
EA-2111
EA-2114
H-2102
PSV-21378
All causes
Mechanical damage
Corrosion
Erosion
Cracking
Tube plugging
Other
Not tagged
3 of 17 - numbers never reused
Generate report
RR #
Unit
Equipment
Asset type
Finding
EWO #
Written by
Written
Stage
Status
RR-012-D-2164
U21
D-2164
Drums
Trays 14 and 15 have two dislodged valve caps and one bent support beam.
—
Kendra J.
11/18/26
Awaiting supervisor review
—
RR-013-EA-2114
U21
EA-2114
Fin Fans
Pitting across the gasket seating face of the channel flange, deepest 0.060 in.
—
Rusty C.
11/19/26
Awaiting supervisor review
—
RR-014-EA-2111
U21
EA-2111
Fin Fans
About 12 sq ft of spalled castable on the north radiant wall, anchors exposed.
—
Wes D.
11/19/26
Awaiting supervisor review
—