Your Inspection Co.
API Inspection / Repair Recommendation
| Site | Calder Bay Complex | RR # | RR-007-E-2129A |
|---|---|---|---|
| Equipment ID | E-2129A | ||
| Process Description | AEL fixed tubesheet | ||
| Inspector | Megan F. | ||
| Date of Finding | 11/15/26 | ||
| EWO / Client WO # | — |
FINDINGS:
During the 2026 U21 Turnaround, visual inspection of E-2129A (AEL fixed tubesheet) — Floating Head revealed: UTT at CML 7 read 0.188 in. against a 0.200 in. retirement thickness.
RECOMMENDATIONS:
Replace the elbow in kind. Add two CMLs downstream.
JUSTIFICATION(S):
No justification recorded.
PHOTO REFERENCE:
No photos attached.