Your Inspection Co.
API Inspection / Repair Recommendation
| Site | Calder Bay Complex | RR # | RR-001-E-2118B |
|---|---|---|---|
| Equipment ID | E-2118B | ||
| Process Description | BEU U-tube | ||
| Inspector | Megan F. | ||
| Date of Finding | 11/12/26 | ||
| EWO / Client WO # | — |
FINDINGS:
During the 2026 U21 Turnaround, visual inspection of E-2118B (BEU U-tube) — Floating Head revealed: Pitting up to 0.090 in. deep in a 6 in. x 8 in. area at the 6 o'clock position of the bottom head. Remaining wall 0.410 in. against a 0.375 in. minimum.
RECOMMENDATIONS:
Clean to bright metal, weld overlay the pitted area, PT after repair.
JUSTIFICATION(S):
No justification recorded.
PHOTO REFERENCE:
No photos attached.